Loading...
Flow through a partially blocked artery downstream of a stented region
Gogineni, Aneesha
Gogineni, Aneesha
Citations
Altmetric:
Files
Loading...
t11064_Gogineni.pdf
Adobe PDF, 1017.4 KB
Authors
Other Names
Location
Time Period
Advisors
Original Date
Digitization Date
Issue Date
2011-07
Type
Thesis
Genre
Keywords
Subjects (LCSH)
Electronic dissertations
Electronic dissertations
Electronic dissertations
Citation
Abstract
A numerical analysis of flow through a stenosed artery downstream of a stented region is presented. Three different Food and Drug Administration (FDA) approved stents (Bx Velocity, NIR, and Multilink Zeta) are considered in analyzing pressure drop and flow rates at the blockage and outlet of artery. Blood flow inside the artery is assumed to be steady. The inlet pressures are defined as the mean arterial pressures in the stented artery using all stages of blood pressures. The pressure drop and volumetric flow rate increases at the blocked artery with increase in mean arterial pressures. In contrast to the previous results the pressure drop and volumetric flow rates decreases at the narrow end of the artery. A comparison was made between all the three different stents which determines the highly optimum stent geometry. An unsteady flow analysis is performed using NIR stent since it is proved to highly optimum when compared to other stents. The velocity and mass flow rates at the outlet are relatively high for unsteady flow rates when compared to steady flow rates. A grid independence study was also performed for all the three stents for accuracy. The obtained results can be used in determining the restenosis rates in patients after NIR stent implantation.
Table of Contents
Description
Thesis (M.S.)--Wichita State University, College of Engineering, Dept. of Mechanical Engineering.
Publisher
Wichita State University
Journal
Book Title
Series
Digital Collection
Finding Aid URL
Use and Reproduction
© Copyright 2011 by Aneesha Gogineni. All rights reserved
