Publication

Hazard-rate tolerance method for an opportunistic-replacement policy

Zheng, Xitong
Fard, Nasser
Citations
Altmetric:
Other Names
Location
Time Period
Advisors
Original Date
Digitization Date
Issue Date
1992-03-31
Type
Article
Genre
Keywords
Failure replacement,Hazard rate,Preventive replacement
Subjects (LCSH)
Research Projects
Organizational Units
Journal Issue
Citation
X. Zheng and N. Fard, "Hazard-rate tolerance method for an opportunistic-replacement policy," in IEEE Transactions on Reliability, vol. 41, no. 1, pp. 13-20, March 1992, doi: 10.1109/24.126664
Abstract
A model is presented for a system with several types of units. A unit is replaced at failure or when its hazard (failure) rate exceeds limit L, whichever occurs first. When a unit is replaced because its hazard rate reaches L, all the operating units with their hazard rate falling in the interval (L – u,L) are replaced. This policy allows joint replacements and avoids the disadvantages resulting from the replacement of new units, down time, and unrealistic assumptions for distributions of unit life. The long-run cost rate is derived. Optimal L and U are obtained to minimize the average total replacement cost rate. Application and analysis of results are demonstrated through a numerical example. © 1992 IEEE
Table of Contents
Description
This is an open access article under the CC by license
Publisher
IEEE
Journal
IEEE Transactions on Reliability
Book Title
Series
Digital Collection
Finding Aid URL
Use and Reproduction
Archival Collection
PubMed ID
ISSN
00189529
EISSN
Embedded videos