Response criterion for determining ipsilateral and contralateral acoustic reflex thresholds using a 1000-Hz probe tone

Loading...
Thumbnail Image
Authors
Derby, Brigid
Advisors
Sun, Xiao-Ming
Issue Date
2020-05-01
Type
Abstract
Keywords
Research Projects
Organizational Units
Journal Issue
Citation
Derby, B. 2020. Response criterion for determining ipsilateral and contralateral acoustic reflex thresholds using a 1000-Hz probe tone -- In Proceedings: 16th Annual Symposium on Graduate Research and Scholarly Projects. Wichita, KS: Wichita State University, p.21
Abstract

INTRODUCTION: The middle-ear cavity between the eardrum and inner ear houses two muscles and three tiny bones. When a loud sound enters the ear, contraction of the stapedius muscle reduces sound transmission of the middle-ear by stiffening the boney chain, helping shield the inner ear from damage. This is known as the acoustic reflex (AR). Clinical AR measurements are applied to help diagnose dysfunctions in the auditory system. During AR testing, a pure tone is presented in the ear canal as the probe signal and another loud sound, to activate the reflex, is presented in the same ear (ipsilateral test) or the other ear (contralateral test). The lowest level of the activator that causes a criterion change in acoustic measure is known as AR threshold (ART). ART testing is typically conducted with a 226-Hz probe tone. However, the resonant frequency of the middle-ear is approximately 1000 Hz in adults. Little research has been done on ARTs tested with a 1000-Hz probe tone in adults, or which response criterion is most reliable. PURPOSE: This study aimed to identify the optimal response criterion for determining ARTs using a 1000-Hz probe tone. METHODS: Data was obtained from 28 participants. Ipsilateral AR tests were run with five activators: four tones (0.5, 1, 2, and 4 kHz) and broadband noise (BBN). Contralateral tests were conducted with 4-kHz tone and BBN. Testing order was randomized. The activator was presented at 60 dB HL, then increased in 5-dB steps. Three ARTs were determined per test as the lowest activator level that caused a criterion change of 0.03, 0.09, and 0.13 mmho, respectively (ART0.03, ART0.09, and ART0.13). RESULTS: Mean data showed that the ipsilateral ART0.13 was approximately 85-90 dB HL for tonal activators and approximately 70 dB HL for BBN. The contralateral ART0.13 was slightly higher (~5 dB). ART0.09 was slightly lower (<5 dB) than ART0.13 for all activators, while the difference reached significance for a few conditions (p<0.05, one-way repeated measures ANOVA on ranks). Standard deviation (SD) was similar between ART0.13 and ART0.09. ART0.03 was significantly lower (~10-20 dB) than ART0.13 for all conditions (p<0.05), but SD was much larger. Detectability of ART0.03 was 100% across all conditions, whereas it was between 78.6--100% for ART0.09, and 71.4--96.4% for ART0.13. Pearson product-moment correlation coefficient was statistically significant between ART0.09 and ART0.13 in all conditions (r=0.59--0.98), but only for two conditions between ART0.03 and ART0.13 (r=0.06--0.53). CONCLUSION: While possible to record lower thresholds using the 0.03 mmho criterion for 1000-Hz ART testing, large individual variation and poor correlation between ART0.03 and ART0.13 exists. Using the 0.09 criterion, greater detectability and lower ARTs can be achieved, compared to the 0.13 criterion. Accordingly, we recommend using the 0.09 mmho response criterion in conducting 1000-Hz ART tests.

Table of Contents
Description
Presented to the 16th Annual Symposium on Graduate Research and Scholarly Projects (GRASP) held online, Wichita State University, May 1, 2020.
Research completed in the Department of Communication Sciences and Disorders, College of Health Professions
Publisher
Wichita State University
Journal
Book Title
Series
GRASP
v. 16
PubMed ID
DOI
ISSN
EISSN