Loading...
Detection and quantification of ketamine HCl in alcohol/water matrices using ESI-MSn and LC-ESI-MS
Lygrisse, Justin ; Lapp, Martin ; Witherspoon, Kelsey
Lygrisse, Justin
Lapp, Martin
Witherspoon, Kelsey
Citations
Altmetric:
Files
Loading...
Conference paper
Adobe PDF, 117.14 KB
Other Names
Location
Time Period
Advisors
Original Date
Digitization Date
Issue Date
2009-05-01
Type
Conference paper
Genre
Keywords
Subjects (LCSH)
Citation
Lygrisse, Justin, Lapp, Martin, Witherspoon, Kelsey and Michael Van Stipdonk (2009). Detection and Quantification of Ketamine HCl in Alcohol/Water Matrices using ESI-MSn and LC-ESI-MS. In Proceedings: 5th Annual Symposium: Graduate Research and Scholarly Projects. Wichita, KS: Wichita State University, p. 48-49
Abstract
Drug facilitated date rape continues to be a problem around the world. Ketamine HCl (KT) has gained popularity since it is nearly odorless, tasteless, and colorless when dissolved in water/alcohol and a typical street dose (300-400mg) only costs $20-$25. A street dose of KT will send the victim into a dissociative state within 10-15 minutes and can cause temporary amnesia. Drug detection is paramount in the prosecution of drug facilitated date rape cases. Currently, detection of KT relies on urine or blood analysis. In this study we have developed a method for detecting and quantifying KT in a variety of different alcohols and mixed drinks. Mass spectrometry (MS) was used to identify the presence of KT in the alcohol matrices. Liquid chromatography (LC) was used to separate the KT from the rest of the alcohol matrix. Quantification of KT was carried out both by MS and LC/UV absorbance using a series of external standards and plotting the concentration versus the signal intensity. Interestingly, it is possible to distinguish not only between different types of alcohol but also different brands of similar alcohol. KT was clearly visible in the spectrum of KT spiked drinks and did not show any interference from the alcohol matrix. Detection limits were found to be in the 100 picoM range and samples were stable for up to 7 days. This method has proven to be robust and a viable way to quantify KT in alcoholic beverages for up to 1 week with very low limits of detection.
Table of Contents
Description
Second Place winner of oral presentations at the 5th Annual Symposium on Graduate Research and Scholarly Projects (GRASP) held at the Hughes Metropolitan Complex, Wichita State University, May 1, 2009.
Research completed at the Department of Chemistry
Research completed at the Department of Chemistry
Publisher
Wichita State University. Graduate School
Journal
Book Title
Series
GRASP
v.5
v.5
