Show simple item record

dc.contributor.authorVo, Tien Minh
dc.contributor.authorVora, Khalil Ur Rehman
dc.contributor.authorMinaie, Bob
dc.date.accessioned2013-10-07T12:47:17Z
dc.date.available2013-10-07T12:47:17Z
dc.date.issued2013-12-05
dc.identifier.citationVo, Tien Minh; Vora, Khalil Ur Rehman; Minaie, Bob. 2013. Effects of postcure temperature variation on hygrothermal-mechanical properties of an out-of-autoclave polymer composite. Journal of Applied Polymer Science, v.130:no.5:pp.3090–3097, December 5, 2013en_US
dc.identifier.issn0021-8995
dc.identifier.otherWOS:000324097400010
dc.identifier.urihttp://dx.doi.org/10.1002/app.39541
dc.identifier.urihttp://hdl.handle.net/10057/6520
dc.descriptionClick on the DOI link to access the article (may not be free).en_US
dc.description.abstractThe effects of cure temperature variation on the properties of an out-of-autoclave polymer composite manufactured using Cycom 5320 8HS prepreg were investigated using different postcure temperatures of a two-stage cure cycle. In addition, the effects of adverse environmental conditions on the cure temperature variation were studied by conditioning the samples in an environmental chamber until they reached moisture equilibrium. The state of cure was obtained using a differential scanning calorimeter and dynamic mechanical analyzer. The mechanical properties were obtained using short-beam shear (SBS) and combined loading compression (CLC) test methods. The state of cure obtained showed increases in total heat of reaction, degree of cure, and glass transition temperature as the postcure temperature increased. The SBS and CLC strengths showed an increasing trend as postcure temperature increased. Good correlations were obtained between the material's cure temperatures, state of cure, and mechanical properties for room temperature dry and hot wet conditions. The study showed that the state of cure can be used to define, monitor, and verify the cure quality. © 2013 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 130: 3090–3097, 2013en_US
dc.language.isoen_USen_US
dc.publisherWiley-Blackwellen_US
dc.relation.ispartofseriesJournal of Applied Polymer Science;v.130:no.5
dc.subjectcompositesen_US
dc.subjectdifferential scanning calorimetryen_US
dc.subjectmechanical propertiesen_US
dc.titleEffects of postcure temperature variation on hygrothermal-mechanical properties of an out-of-autoclave polymer compositeen_US
dc.typeArticleen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record