Biomedical Engineering
Browse by
Recent Submissions
-
Ultrahigh conductivity and superior interfacial adhesion of a nanostructured, photonic-sintered copper membrane for printed flexible hybrid electronics
(American Chemical Society, 2018-11-19)Inkjet-printed electronics using metal particles typically lack electrical conductivity and interfacial adhesion with an underlying substrate. To address the inherent issues of printed materials, this Research Article ... -
Migration through a small pore disrupts inactive chromatin organization in neutrophil-like cells
(BioMed Central Ltd., 2018-11-26)Background. Mammalian cells are flexible and can rapidly change shape when they contract, adhere, or migrate. The nucleus must be stiff enough to withstand cytoskeletal forces, but flexible enough to remodel as the cell ... -
Passive self resonant skin patch sensor to monitor cardiac intraventricular stroke volume using electromagnetic properties of blood
(IEEE, 2018-09-26)This paper focuses on the development of a passive, lightweight skin patch sensor that can measure fluid volume changes in the heart in a non-invasive, point-of-care setting. The wearable sensor is an electromagnetic, ... -
The effects of a fatiguing lifting task on postural sway among males and females
(Elsevier, 2018-06)Lifting and falls comprise a large proportion of work related injuries. Repetitive lifting to the point of fatigue can affect postural sway, which is associated with fall risk. To investigate the effects of lifting and ... -
Non-invasive electromagnetic skin patch sensor to measure intracranial fluid–volume shifts
(MDPI, Basel, Switzerland, 2018-03-29)Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for ... -
Fabrication of magnesium-based metallic scaffolds for bone tissue engineering
(Taylor & Francis, 2018)Repairing and regenerating defects of large bones caused by disease or trauma is a significant clinical challenge. Extensive research has been done on bone tissue regeneration incorporating biodegradable scaffolds mainly ... -
Editorial: Metallic biomaterials
(Taylor & Francis, 2018)Metals in biomedical devices are exploited due to their inertness and structural functions. Several opportunities exist for implantable metallic biomaterials to enhance the bio functionality of current metallic biomaterials ... -
Preliminary validation of a dynamic electrochemical biodegradation test bench in pseudo-physiological conditions
(Taylor & Francis, 2018)There is a growing interest in the development of next-generation stent materials. In vitro tests that accurately predict in vivo conditions are desired. In this manuscript, a novel approach for the design of a dynamic ... -
Passive wearable skin patch sensor measures limb hemodynamics based on electromagnetic resonance
(IEEE, 2018-04)Objective: The objectives of this study were to design and develop an open-circuit electromagnetic resonant skin patch sensor, characterize the fluid volume and resonant frequency relationship, and investigate the sensor's ... -
Concurrent validity of heart rate measures using a wrist worn activity tracker during treadmill walking
(Wichita State University, 2018-04-27)Introduction: Wearable technology devices are becoming increasingly popular. Many of these devices offer features allowing users to monitor health related biometric information. One biometric variable commonly measured is ... -
Electro-poroelastohydrodynamics of the endothelial glycocalyx layer
(Cambridge University Press, 2018-03-10)We consider pressure-driven flow of an ion-carrying viscous Newtonian fluid through a non-uniformly shaped channel coated with a charged deformable porous layer, as a model for blood flow through microvessels that are lined ... -
Analysis of ischemic muscle in patients with peripheral artery disease using X-ray spectroscopy
(Elsevier, 2017-12)Background: Peripheral artery disease (PAD) is a vascular disease caused by atherosclerosis, resulting in decreased blood flow to the lower extremities. The ankle-brachial index (ABI) is a standard PAD diagnostic test but ... -
Non-invasive point-of-care method for measuring left-ventricular stroke-volume using a passive electromagnetic skin patch sensor
(Elsevier Inc., 2017-03-21)The aim of this study was to develop a non-invasive mobile skin patch sensor – applied like an adhesive bandage which could potentially measure left-ventricular stroke volume (LVSV). -
Non-invasive biomedical patch sensor to measure intracranial pressure
(IEEE, 2016)This study was focused on the development of a non-invasive mobile skin sensor for measuring intracranial pressure (ICP). Current techniques are limited to surgical implantations or methods that require highly specialized ... -
Nanostructured self assembled monolayers on magnesium for improved biological performance
(Taylor & Francis LTD, 2016)Magnesium (Mg) and its alloys are being extensively investigated for its use as a biodegradable metallic implant material. Surface modification strategies are critical for Mg to be able to address application-specific ... -
An evaluation of the state of neuromuscular blockade monitoring devices
(Springer International Publishing, 2016-12)A core element of anesthesia care is the use of intravenous muscle relaxants. While neuromuscular blockade (NMB) monitoring devices assess the degree of patient paralysis, few clinically convenient monitors exist. The lack ... -
Determination of yolk contamination in liquid egg white using Raman spectroscopy
(Oxford University Press, 2016-07)Purified egg white is an important ingredient in a number of baked and confectionary foods because of its foaming properties. However, yolk contamination in amounts as low as 0.01% can impede the foaming ability of egg ... -
Bio-functional nano-coatings on metallic biomaterials
(Elsevier B.V., 2015-10-01)Metals and their alloys have been widely used in all aspects of science, engineering and medicine. Metals in biomedical devices are used due to their inertness and structural functions. They are generally preferred over ... -
Mathematical modeling of the electrodeposition process
(Electrochemical Society, 2014-05-11)Electroplating or electrodeposition is a process which produces a dense, uniform and adherent coating on a metal surface using electric current in an electrolytic cell. This process is mainly used to change the surface ... -
Chapter 11 -- Biodegradable carrier systems for drug and vaccine delivery
(River Publishers, 2015-04)Understanding the molecular mechanisms of cancer is the key for transforming cancer medicine. A substantial proportion of human genes show alternative splicing and mis-regulation of Pre-mRNA splicing is seen in several ...