    Nanomonitors: a miniature electronic biosensor for early disease diagnosis

    View
    Savindra_Brandigampala_CGRS_8_2011.pdf
    Download
    Savindra_Brandigampala_CGRS_8_2011.pdf
     
    Date
    2011-02-17
    Author
    Brandigampala, Savindra Madhavi
    Prasad, Shalini
    Metadata
    Show full item record
    Abstract
    Heart disease more specifically vulnerable coronary plaque rupture, which is the cause of acute coronary syndromes stroke, peripheral vascular limb ischemia, and other end-organ ischemic diseases, is one of the leading causes of death in Kansas. Approximately 50% of Kansas population lives in rural areas and 13% of Kansas population are above 65 years, an age group where ACI (Acute Coronary Insufficiency) is one of the major causes of death. More importantly approximately 13% of Kansas population does not have health insurance. Hence, it becomes essential to develop technologies, which enable rapid and cost effective diagnosis of ACI in a pre-symptomatic state. The primary purpose of this research is to develop an inexpensive and user friendly ‘point- of- care’ (POC) device for pre-symptomatic diagnosis of ACI through the detection of two proteins that have been identified as biomarkers for this disease. Inflammation and thrombosis are key mediators of vulnerable coronary plaque and NT-BNP and Troponin-T are two proteins which are biomarkers of this condition. We have utilized nanoporous alumina membranes to generate high surface area to volume structures for trapping protein biomolecules. We employ the protein specific capacitance measurement method as the basis for protein biomarker detection. We demonstrate device performance parameters for protein biomarker detection in purified and spiked serum samples to be comparable to the current gold standard: ELISA.
    Description
    The project completed at the Wichita State University Department of Electrical Engineering and Computer Science. Presented at the 8th Annual Capitol Graduate Research Summit, Topeka, KS, 2011
    URI
    http://hdl.handle.net/10057/5482
    Collections
    • Abstracts: 8th Annual Capitol Graduate Research Summit [10]

    SOAR is a service of Wichita State University Libraries
    Contact Us | Send Feedback
    Site statistics 
     

     

    Browse

    All of SOARCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeThis CollectionBy Issue DateAuthorsTitlesSubjectsType

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    SOAR is a service of Wichita State University Libraries
    Contact Us | Send Feedback
    Site statistics