Show simple item record

dc.contributor.authorGriffith, Jacob L.
dc.contributor.authorCluff, Kim
dc.contributor.authorDownes, Grant M.
dc.contributor.authorEckerman, Brandon
dc.contributor.authorBhandari, Subash
dc.contributor.authorLoflin, Benjamin E.
dc.contributor.authorBecker, Ryan
dc.contributor.authorAlruwaili, Fayez H.
dc.contributor.authorMohammed, Noor
dc.date.accessioned2023-02-06T21:46:05Z
dc.date.available2023-02-06T21:46:05Z
dc.date.issued2023-01-14
dc.identifier.citationGriffith JL, Cluff K, Downes GM, Eckerman B, Bhandari S, Loflin BE, Becker R, Alruwaili F, Mohammed N. Wearable Sensing System for NonInvasive Monitoring of Intracranial BioFluid Shifts in Aerospace Applications. Sensors. 2023; 23(2):985. https://doi.org/10.3390/s23020985
dc.identifier.issn1424-8220
dc.identifier.urihttps://doi.org/10.3390/s23020985
dc.identifier.urihttps://soar.wichita.edu/handle/10057/24999
dc.descriptionThis article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
dc.description.abstractThe alteration of the hydrostatic pressure gradient in the human body has been associated with changes in human physiology, including abnormal blood flow, syncope, and visual impairment. The focus of this study was to evaluate changes in the resonant frequency of a wearable electromagnetic resonant skin patch sensor during simulated physiological changes observed in aerospace applications. Simulated microgravity was induced in eight healthy human participants (n = 8), and the implementation of lower body negative pressure (LBNP) countermeasures was induced in four healthy human participants (n = 4). The average shift in resonant frequency was −13.76 ± 6.49 MHz for simulated microgravity with a shift in intracranial pressure (ICP) of 9.53 ± 1.32 mmHg, and a shift of 8.80 ± 5.2097 MHz for LBNP with a shift in ICP of approximately −5.83 ± 2.76 mmHg. The constructed regression model to explain the variance in shifts in ICP using the shifts in resonant frequency (R2 = 0.97) resulted in a root mean square error of 1.24. This work demonstrates a strong correlation between sensor signal response and shifts in ICP. Furthermore, this study establishes a foundation for future work integrating wearable sensors with alert systems and countermeasure recommendations for pilots and astronauts.
dc.language.isoen_US
dc.publisherMDPI
dc.relation.ispartofseriesSensors
dc.relation.ispartofseriesVolume 23, No. 2
dc.subjectElectromagnetic sensing
dc.subjectIntracranial pressure
dc.subjectMicrogravity
dc.subjectLower body negative pressure
dc.subjectRF resonator
dc.titleWearable sensing system for noninvasive monitoring of intracranial biofluid shifts in aerospace applications
dc.typeArticle
dc.rights.holder© 2023 by the authors.


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record