• Login
    View Item 
    •   Shocker Open Access Repository Home
    • Engineering
    • Biomedical Engineering
    • BioMed Engineering Research
    • BIOMED Research Publications
    • View Item
    •   Shocker Open Access Repository Home
    • Engineering
    • Biomedical Engineering
    • BioMed Engineering Research
    • BIOMED Research Publications
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Smart bioelectronic pacifier for real-time continuous monitoring of salivary electrolytes

    Date
    2022-05-16
    Author
    Lim, Hyo-ryoung
    Lee, Soon Min
    Park, Sehyun
    Choi, Chanyeong
    Kim, Hojoong
    Kim, Jihoon
    Mahmood, Musa
    Lee, Yongkuk
    Kim, Jong-Hoon
    Yeo, Woon-Hong
    Metadata
    Show full item record
    Citation
    Lim, H.-R., Lee, S. M., Park, S., Choi, C., Kim, H., Kim, J., . . . Yeo, W.-H. (2022). Smart bioelectronic pacifier for real-time continuous monitoring of salivary electrolytes. Biosensors and Bioelectronics, 210. https://doi.org/https://doi.org/10.1016/j.bios.2022.114329
    Abstract
    Monitoring electrolytes is critical for newborns and babies in the intensive care unit. However, the gold standard methods use a blood draw, which is painful and only offers discrete measures. Although salivary-based detection offers promise as an alternative, existing devices are ineffective for real-time, continuous monitoring of electrolytes due to their rigidity, bulky form factors, and lack of salivary accumulation. Here, we introduce a smart, wireless, bioelectronic pacifier for salivary electrolyte monitoring of neonates, which can detect real-time continuous sodium and potassium levels without a blood draw. The miniature system facilitates the seamless integration of the ultralight and low-profile device with a commercial pacifier without additional fixtures or structural modifications. The portable device includes ion-selective sensors, flexible circuits, and microfluidic channels, allowing simplified measurement protocols in non-invasive electrolyte monitoring. The flexible microfluidic channel enables continuous and efficient saliva collection from a mouth. By modifying the surface properties of the channels and the structure of the capillary reservoir, we achieve reliable pumping of the viscous medium for quick calibration and measurement. Embedded sensors in the system show good stability and sensitivity: 52 and 57 mV/decade for the sodium and potassium sensor, respectively. In vivo study with neonates in the intensive care unit captures the device's feasibility and performance in the natural saliva-based detection of the critical electrolytes without induced stimulation.
    Description
    Click on the DOI to access this article (may not be free).
    URI
    https://doi.org/10.1016/j.bios.2022.114329
    https://soar.wichita.edu/handle/10057/23316
    Collections
    • BIOMED Research Publications

    Browse

    All of Shocker Open Access RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Type

    My Account

    LoginRegister

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    DSpace software copyright © 2002-2022  DuraSpace
    DSpace Express is a service operated by 
    Atmire NV