• Login
    View Item 
    •   Shocker Open Access Repository Home
    • Applied Studies
    • Human Performance Studies (HPS)
    • HPS Research Publications
    • View Item
    •   Shocker Open Access Repository Home
    • Applied Studies
    • Human Performance Studies (HPS)
    • HPS Research Publications
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Accuracy of the SWAY mobile cognitive assessment application

    View/Open
    Article (390.7Kb)
    Date
    2021
    Author
    VanRavenhorst-Bell, Heidi A.
    Muzeau, Melissa A.
    Luinstra, Lindsay
    Goering, Jared
    Amick, Ryan Zackary
    Metadata
    Show full item record
    Citation
    Vanravenhorst-Bell, H. A., Muzeau, M. A., Luinstra, L., Goering, J., & Amick, R. Z. (2021). Accuracy of the SWAY mobile cognitive assessment application. International Journal of Sports Physical Therapy, 16(4), 991-1000. doi:10.26603/001c.24924
    Abstract
    Background Mobile electronic devices have become integral tools in addressing the need for portable assessment of cognitive function following neurocognitive/motor injury. SWAY Medical, Inc., has employed mobile device motion-based technology in the SWAY Cognitive Assessment (SWAY CA) application to assess cognitive function. Purpose The purpose of this study was to assess whether the SWAY CA application (reaction time, impulse control and inspective time) was able to reliably operate on different mobile devices and operating systems (iOS, Android). The study further sought to assess the validity of the SWAY CA application against the FDA approved ImPACT QT mobile device application. Study Design Original Research, observational study of validity. Methods 88 healthy, young adults, 18 to 48 years (mean= 22.09 ± sd=4.47 years) completed four, randomized and counter-balanced, reaction time tests (2- SWAY RT, 2- ImPACT QT) using different operating systems (iOS, Android) of 4 randomly assigned mobile devices. Results ANOVAs reported the SWAY CA application (reaction time, impulse control, inspection time) operated reliably with iPhone 6S, Samsung Galaxy S9, and iPad Pro 5 mobile devices (p > 0.05), respectively. Google Pixel 3 reliability with SWAY CA application remains undetermined. SWAY CA simple reaction motion measures were in agreement (r = -0.46 to 0.22, p ≤ 0.05) with several ImPACT QT reaction time measures. SWAY CA impulse control and inspection time measures are weakly correlated (r = -0.25 to -0.46, p ≤ 0.05) with five ImPACT QT reaction time measures. Conclusion The motion-based SWAY CA mobile device application appears to reliably operate when being administered on different mobile devices and software operating systems. Furthermore, the SWAY CA application appears to be comparable to the ImPACT QT and serve as a valid tool for assessing reaction time measures.
    Description
    This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CCBY-NC-SA-4.0). View this license’s legal deed at https://creativecommons.org/licenses/by-nc-sa/4.0 and legal code at https://creativecommons.org/licenses/by-nc-sa/4.0/legalcode for more information.
    URI
    https://doi.org/10.26603/001c.24924
    https://soar.wichita.edu/handle/10057/22319
    Collections
    • HPS Research Publications

    Browse

    All of Shocker Open Access RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Type

    My Account

    LoginRegister

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    DSpace software copyright © 2002-2023  DuraSpace
    DSpace Express is a service operated by 
    Atmire NV