dc.description.abstract | A large portion of occupational low back disorders (OLBDs) are due to industrial lifting
activities. Prior research has clearly demonstrated the association between the external loadings
and the risk of OLBD. Low back moments generated internally to counteract external loadings
are believed to be the most significant risk factor for OLBD. The increase of both load weight
and the horizontal distance between the load and the body (moment arm) increase the external
loadings. To accurately assess the risk of OLBD, practitioners need to accurately estimate the
external moment using an accurate measurement of the moment arm.
The first study assessed the accuracy of manual moment arm measurements during
various lifting conditions as compared to a motion capturing system measurements. The second
study examined the accuracy of a video-based analysis software (VAS) in measuring the
moment arm distance as compared to a motion capturing system. The third study examined the
effect of different camera vertical heights on the accuracy of the measured moment arms.
Manual moment arm measurements resulted in an average absolute error (AAE) of
6.21cm for lift origin moment arms. VAS moment arm measurements obtained from video
recordings via 90° webcam showed a lower AAE (4.25 cm) as compared to measurement errors
from 30° and 60° webcams (17.29 cm and 6.07 cm, respectively). The lower webcam height
provided measurements with a smaller error (AAE = 3.90 cm) as compared to measurements
from the upper webcam (AAE = 11.84 cm).
Manual moment arm measurements encountered greater errors as compared to VAS
measurements using 90° webcam. This error could further increase when assessing lifting jobs
in the field, where practitioners may not get the chance to manually measure the moment arm
from a close distance. Videos recorded from webcams with a line of sight almost perpendicular
to the lifter’s forearm during lifting resulted in more accurate measurements via the VAS
approach. | |
dc.format.extent | xiv, 156 pages | |
dc.language.iso | en_US | |
dc.publisher | Wichita State University | |
dc.rights | Copyright 2020 by Khaled Abdulrashid Hafez
All Rights Reserved | |
dc.subject.lcsh | Electronic dissertation | |
dc.title | Accuracy of video-based moment arm measurements and use with occupational low back disorder assessment methods | |
dc.type | Dissertation | |