    Cardiac failure detection using a wearable patch sensor in a point-of-care setting

    View/Open
    Abstract (56.34Kb)
    Date
    2019-02-26
    Author
    Alruwaili, Fayez H.
    Bhandari, Subash
    Advisor
    Cluff, Kim; Farhoud, Hussam
    Metadata
    Show full item record
    Abstract
    The importance of ventricular stroke volume (SV) for the detection of cardiac failure has been well established in the clinical field. The focus of this study was to develop a simple to use sensor that could be applied like an adhesive bandage that could potentially measure SV, and subsequently aid in the detection of cardiac failure. A patch sensor was designed from a trace of a copper configured into a square planar spiral. The patch sensor self-resonates when impinged upon by a specific range of radio frequency (RF) waves. Human participants (n = 5) were recruited to measure SV using the patch sensor and the data was compared against a clinical standard (impedance cardiography). Shifts in the resonance were registered as blood volume changes throughout the cardiac cycle. A statistical correlation analysis was performed to determine the patch sensor's performance in measuring SV, heart rate (HR), and cardiac output (CO). Changes in the effective permittivity in the aortic arch (AO) due to changes in blood volume were directly correlated to the measurements of SV. SV, HR, and CO were measured with the patch sensor with a 94.0 % accuracy as compared to the clinical standard impedance cardiography. This work presents a foundation for the development of a patch sensor that may be used as a non-invasive diagnostic to detect cardiac failure for people that live in low resource environments or have limited access to medical care.
    Description
    Poster project completed at the Wichita State University Department of Biomedical Engineering. Presented at the 16th Annual Capitol Graduate Research Summit, Topeka, KS, February 26, 2019.
    URI
    http://hdl.handle.net/10057/16425
    Collections
    • 2019 WSU Annual CGRS Abstracts

    Browse

    All of Shocker Open Access RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Type

    My Account

    LoginRegister

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    DSpace software copyright © 2002-2023  DuraSpace
    DSpace Express is a service operated by 
    Atmire NV