Show simple item record

dc.contributor.authorAsmatulu, Ramazan
dc.contributor.authorVeisi, Zeinab
dc.contributor.authorUddin, M. Nizam
dc.contributor.authorMahapatro, Anil
dc.date.accessioned2019-06-26T15:17:59Z
dc.date.available2019-06-26T15:17:59Z
dc.date.issued2019-05
dc.identifier.citationAsmatulu, R., Veisi, Z., Uddin, M.N. et al. Fibers Polym (2019) 20: 966en_US
dc.identifier.issn1229-9197
dc.identifier.otherWOS:000469219300010
dc.identifier.urihttps://doi.org/10.1007/s12221-019-1096-x
dc.identifier.urihttp://hdl.handle.net/10057/16373
dc.descriptionClick on the DOI link to access the article (may not be free).en_US
dc.description.abstractHighly sensitive, reliable and practical detection of Cyclooxygenase-2 (COX-2) as an important enzyme in pain biomarkers, inflammation, and cancer cell proliferation is of great importance. This study demonstrates the feasibility of developing nanobiosensor (or biosensor) platforms for sensitive COX-2 biomarker detection from phosphate buffer saline (PBS) and human serum samples. Highly porous polyaniline nanofibers were fabricated in four different average diameters using electrospinning process. They were then integrated as the main sensing component into interdigitated gold microelectrodes to develop label-free electrochemical nanobiosensors. The performance of the nanobiosensors was evaluated in comparison with a plain control biosensor using electrochemical impedance spectroscopy (EIS). Significant improvement was observed in the sensitivity of the nanofiber-based biosensors revealing the remarkable capability of electrospun polyaniline nanofiber in robust and rapid detection of the COX-2 biomarker. The fabricated nanofiber-based biosensors were able to detect the target antigen with concentrations as low as 0.01 pg/ml in PBS and human serum samples, respectively. High sensitivity, as well as remarkable selectivity towards COX-2 analyte, suggested the excellent potential of this nanofiber-based platform for reliable COX-2 analyte detection.en_US
dc.description.sponsorshipWichita State University and National Institute for Aviation Research for technical and financial support of the present research studies.en_US
dc.language.isoen_USen_US
dc.publisherKorean Fiber Societyen_US
dc.relation.ispartofseriesFibers and Polymers;v.20:no.5
dc.subjectElectrospun nanofibersen_US
dc.subjectElectrochemical impedance spectroscopyen_US
dc.subjectBiosensoren_US
dc.subjectCOX-2 Enzyme detectionen_US
dc.titleHighly sensitive and reliable electrospun polyaniline nanofiber based biosensor as a robust platform for COX-2 enzyme detectionsen_US
dc.typeArticleen_US
dc.rights.holder© 2019, The Korean Fiber Societyen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.