Show simple item record

dc.contributor.advisorPang, ChengZong
dc.contributor.authorMittapally, Sravan Kumar
dc.date.accessioned2018-09-18T21:31:05Z
dc.date.available2018-09-18T21:31:05Z
dc.date.issued2018-05
dc.identifier.othert18020
dc.identifier.urihttp://hdl.handle.net/10057/15488
dc.descriptionThesis (M.S.)-- Wichita State University, College of Engineering, Dept. of Electrical Engineering and Computer Science
dc.description.abstractConventionally transmission line power transfer capability can be increased by inserting the series compensation into the transmission lines. Though series compensation is an economical solution compared to building a new transmission line, it brings the risk of Sub-Synchronous Resonance in turbine-generator system-based power plants. In literature mitigation of SSR was actively studied using wind turbine generators and FACTS devices, where certain type of WTGs is vulnerable to SSR and FACTS devices are expensive and are not capable to exchange active power with the grid. The structure of PV farms can bring the can bring the capabilities of WTGs and FACTS devices together while addressing their problems at the same time. Among different renewables wind and solar are the fastest growing, according to DOE SunShot initiative studies by 2050 solar serves an estimated 27% of the U.S. electricity needs. The rapid growth in utility connected PV farms has opened new possibilities, and due to its flexibility and dispatchability PV farms can handle the grid support functions more effectively, whereas its ability to mitigate the SSR is rarely investigated. This thesis addresses the potential of PV Power Station to mitigate SSR problem particularly torque amplification in series compensated systems by augmenting the GSC control loop with damping controller using a control signal which is closely related to the network resonant mode, utility scale PV farms are a promising solution to combat the increasing demand and grid support functions simultaneously. The simulation studies are performed in MATLAB/Simulink software using IEEE Second Benchmark Model (SBM) for SSR studies.
dc.format.extentxii, 40 pages
dc.language.isoen_US
dc.publisherWichita State University
dc.rightsCopyright 2018 by Sravan Kumar Mittapally All Rights Reserved
dc.subject.lcshElectronic dissertation
dc.titleAnalysis and mitigating of subsynchronous resonance in power system integrated with PV Power Station
dc.typeThesis


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record