dc.contributor.authorGriffith, Jacob L.
dc.contributor.authorCluff, Kim
dc.contributor.authorEckerman, Brandon
dc.contributor.authorAldrich, Jessica
dc.contributor.authorBecker, Ryan A.
dc.contributor.authorMoore-Jansen, Peer H.
dc.contributor.authorPatterson, Jeremy A.
dc.date.accessioned2018-06-04T16:14:46Z
dc.date.available2018-06-04T16:14:46Z
dc.date.issued2018-03-29
dc.identifier.citationJacob Griffith, Kim Cluff, Brandon Eckerman, Jessica Aldrich, Ryan Becker, Peer Moore-Jansen, and Jeremy Patterson. 2018. Non-Invasive electromagnetic skinp atch sensor to measure intracranial fluid–volume shifts. Sensors (Basel). 2018 Apr; 18(4): 1022.en_US
dc.identifier.issn1424-8220
dc.identifier.urihttp://dx.doi.org/10.3390/s18041022
dc.identifier.urihttp://hdl.handle.net/10057/15240
dc.descriptionCopyright © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).en_US
dc.description.abstractElevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments) were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure.en_US
dc.language.isoen_USen_US
dc.publisherMDPI, Basel, Switzerlanden_US
dc.relation.ispartofseriesSensors: an Open Access Journal;
dc.relation.ispartofseriesSensors;v.8, iss.4
dc.subjectDielectricsen_US
dc.subjectHealth monitoring systemsen_US
dc.subjectIntracranial pressure sensorsen_US
dc.subjectMicrowave sensorsen_US
dc.subjectPoint-of-care technologiesen_US
dc.subjectVolume measurementen_US
dc.subjectWearable sensorsen_US
dc.titleNon-invasive electromagnetic skin patch sensor to measure intracranial fluid–volume shiftsen_US
dc.typeArticleen_US
dc.rights.holder© 2018 by the authorsen_US