    Non-invasive electromagnetic skin patch sensor to measure intracranial fluid–volume shifts

    View/Open
    research article (18.13Mb)
    Date
    2018-03-29
    Author
    Griffith, Jacob L.
    Cluff, Kim
    Eckerman, Brandon
    Aldrich, Jessica
    Becker, Ryan A.
    Moore-Jansen, Peer H.
    Patterson, Jeremy A.
    Metadata
    Show full item record
    Citation
    Jacob Griffith, Kim Cluff, Brandon Eckerman, Jessica Aldrich, Ryan Becker, Peer Moore-Jansen, and Jeremy Patterson. 2018. Non-Invasive electromagnetic skinp atch sensor to measure intracranial fluid–volume shifts. Sensors (Basel). 2018 Apr; 18(4): 1022.
    Abstract
    Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments) were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure.
    Description
    Copyright © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
    URI
    http://dx.doi.org/10.3390/s18041022
    http://hdl.handle.net/10057/15240
    Collections
    • ANTH Research Publications
    • BIOMED Research Publications
    • HPS Research Publications

    Browse

    All of Shocker Open Access RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Type

    My Account

    LoginRegister

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    DSpace software copyright © 2002-2023  DuraSpace
    DSpace Express is a service operated by 
    Atmire NV