Show simple item record

dc.contributor.authorHanumantha Vajjala, Vivek Abhilash
dc.contributor.authorJewell, Ward T.
dc.date.accessioned2016-09-25T23:13:52Z
dc.date.available2016-09-25T23:13:52Z
dc.date.issued2015
dc.identifier.citationV. A. H. Vajjala and W. Jewell, "Demand response potential in aggregated residential houses using GridLAB-D," Technologies for Sustainability (SusTech), 2015 IEEE Conference on, Ogden, UT, 2015, pp. 27-34.en_US
dc.identifier.isbn978-1-4799-1802-7
dc.identifier.otherWOS:000380536300005
dc.identifier.urihttp://dx.doi.org/10.1109/SusTech.2015.7314317
dc.identifier.urihttp://hdl.handle.net/10057/12437
dc.descriptionClick on the DOI link to access the article (may not be free).en_US
dc.description.abstractAggregating houses and then applying a demand response (DR) program yields considerable benefit to both users and utility companies. This aggregation can prove beneficial to the utility because they can obtain an estimate of how much energy consumption can be reduced at a given point in time. The aggregator would coordinate between the company and the consumer to provide the demand reduction. In this research work, a group of simulated houses sharing the same climatic and geographical conditions were aggregated. They were simulated for a DR using a direct load control (DLC) program, whereby only the heating ventilation and air conditioning (HVAC) system was turned off for one ten-minute period in each of these houses, and the DR program was run for a two-hour period during peak load. Also, energy reductions resulting from the energy efficiency of the houses were simulated and then supplemented with a DR to see how they affect power consumption and how beneficial this would be to the utility. Increasing the thermal integrity levels on the houses decreased the DR potential, but a considerable drop in energy consumption itself was observed, which could prove beneficial in the long term. A co-related pattern was observed among different populations of houses, each of which had a different floor area but the same-size HVAC size and the same thermal integrity levels.en_US
dc.language.isoen_USen_US
dc.publisherIEEEen_US
dc.relation.ispartofseries2015 IEEE Conference on, Ogden, UT, Technologies for Sustainability (SusTech);
dc.subjectLoad managementen_US
dc.subjectPower demanden_US
dc.subjectReal-time systemsen_US
dc.subjectMeteorologyen_US
dc.subjectFloorsen_US
dc.subjectWater heatingen_US
dc.subjectAtmospheric modelingen_US
dc.titleDemand response potential in aggregated residential houses using GridLAB-Den_US
dc.typeConference paperen_US
dc.rights.holder© Copyright 2016 IEEE - All rights reserved.en_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record