Loading...
Thumbnail Image
Publication

Development of flexible ion-selective electrodes for saliva sodium detection

Lim, Hyo-ryoung
Lee, Soon-min
Mahmood, Musa
Kwon, Shinjae
Kim, Yunsoung
Lee, Yongkuk
Yeo, Woon-Hong
Citations
Altmetric:
Other Names
Location
Time Period
Advisors
Original Date
Digitization Date
Issue Date
2021-03
Type
Article
Genre
Keywords
Saliva-to-blood sodium levels,Electrochemical sensor,Ion-selective electrode,Non-invasive diagnosis
Subjects (LCSH)
Research Projects
Organizational Units
Journal Issue
Citation
Lim, H. -., Lee, S. M., Mahmood, M., Kwon, S., Kim, Y. -., Lee, Y., & Yeo, W. -. (2021). Development of flexible ion-selective electrodes for saliva sodium detection. Sensors, 21(5), 1-11. doi:10.3390/s21051642
Abstract
Saliva can be used for health monitoring with non-invasive wearable systems. Such devices, including electrochemical sensors, may provide a safe, fast, and cost-efficient way of detecting target ions. Although salivary ions are known to reflect those in blood, no available clinical device can detect essential ions directly from saliva. Here, we introduce an all-solid-state, flexible film sensor that allows highly accurate detection of sodium levels in saliva, comparable to those in blood. The wireless film sensor system can successfully measure sodium ions from a small volume of infants’ saliva (<400 µL), demonstrating its potential as a continuous health monitor. This study includes the structural characterization and error analysis of a carbon/elastomer-based ion-selective electrode and a reference electrode to confirm the signal reliability. The sensor, composed of a pair of the electrodes, shows good sensitivity (58.9 mV/decade) and selectivity (log K = −2.68 for potassium), along with a broad detection range of $5 × 10^{-5}$ ≈ 1 M with a low detection limit of $4.27 × 10^{-5}$ M. The simultaneous comparison between the film sensor and a commercial electrochemical sensor demonstrates the accuracy of the flexible sensor and a positive correlation in saliva-to-blood sodium levels. Collectively, the presented study shows the potential of the wireless ion-selective sensor system for a non-invasive, early disease diagnosis with saliva.
Table of Contents
Description
Copyright: © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).
Publisher
MDPI
Journal
Book Title
Series
Sensors;Vol. 21, Iss. 5
Digital Collection
Finding Aid URL
Use and Reproduction
Archival Collection
PubMed ID
DOI
ISSN
1424-8220
EISSN
Embedded videos