Publication

Enhanced pool boiling critical heat flux on tilted heating surfaces using columnar-post wicks

Borumand, Mohammad
Hwang, Gisuk
Citations
Altmetric:
Other Names
Location
Time Period
Advisors
Original Date
Digitization Date
Issue Date
2022-01-25
Type
Article
Genre
Keywords
Hydrodynamic-instability wavelength,Chocking limit,Capillary flow,Interfacial lift-off model,Liquid-vapor phase separation
Subjects (LCSH)
Research Projects
Organizational Units
Journal Issue
Citation
Borumand, M, & Hwang, G. "Enhanced Pool Boiling Critical Heat Flux on Tilted Heating Surfaces Using Columnar-Post Wicks." Proceedings of the ASME 2021 International Mechanical Engineering Congress and Exposition. Volume 11: Heat Transfer and Thermal Engineering. Virtual, Online. November 1–5, 2021. V011T11A028. ASME. https://doi.org/10.1115/IMECE2021-70054
Abstract
The upper heat flux limit of nucleate pool-boiling heat transfer (NPHT), i.e., Critical Heat Flux (CHF), results in system burnouts in various energy and industrial applications, and the understandings of the tailored CHF mechanisms are crucial to develop robust thermal management systems. In various applications, the understandings of the tailored CHF mechanisms are essential for design flexibility and operation sustainability, but previous CHF tailoring studies focused on upward-facing heater orientation. This study examines the tailored hydrodynamic-instability using columnar post wick array to enhance CHF on tilted heater surfaces (with surface orientation θ = 60°–130°). Liquid supply enhances via the capillary flow through the post wicks, while the produced vapor efficiently escapes through pore space among the post wicks. The enhanced CHF are predicted using a modified interfacial lift-off CHF hydrodynamic model that relies on classical two-dimensional interfacial instability theory. On the tilted plain surface with the surface orientation from 60° to 130°, the model predicts the CHF, qCHF = 126.5 to 92.5 W/cm2 at the critical hydrodynamic instability wavelength, λcr = 9.2 to 12.7 mm, respectively, using water as a working fluid. The enhanced CHF is predicted at the surface orientations of θ = 90° and 120°, showing a maximum of 185% and 250% increase, respectively. The maximum enhancement occurs at the smallest columnar-post pitch distances, lp = 2.5 mm, where qCHF increases from 104 to 295 W/cm2 for θ = 90°, and from 89 to 313 W/cm2 for θ = 120°. The developed model will provide insights into the tailored hydrodynamic instability wavelength at tilted angle via engineered surface.
Table of Contents
Description
Click on the DOI link to view this conference paper (may not be free).
Publisher
ASME
Journal
Book Title
Series
ASME 2021 International Mechanical Engineering Congress and Exposition;2021
Digital Collection
Finding Aid URL
Use and Reproduction
Archival Collection
PubMed ID
DOI
ISSN
978-0-7918-8567-3
EISSN
Embedded videos