| Citation: | Sappok, Cindy, Lennington, Kimmie , Harrell, Katie (2008). Accuracy of pedometer steps and time for youth with developmental disabilities during dynamic movements. In Proceedings: 4th Annual Symposium: Graduate Research and Scholarly Projects. Wichita, KS: Wichita State University, p.37-38 |
| Series/Report no.: | GRASP v.4 |
| Abstract: | Pedometers are a valid measure of walking behaviors of youth with and without disabilities. Walking is only one
of the many types of movements in which youth engage. Given the dynamic/sporadic nature of youth’s activity patterns, the
need arises to examine whether pedometers can accurately record activities other than walking. Sixteen youth with
developmental disabilities (9 girls, 7 boys, 13.4 ± 3.8yrs) were videotaped for five minutes during adapted physical
education (APE) class while wearing five Walk4Life 2505 pedometers placed in five locations around waist (front right and
left, and back right, middle, and left). Subjects engaged in activities consistent with their APE curriculum (e.g., playing
catch, volleyball). Researchers viewed each videotape and recorded actual steps and activity time. Findings of each
researcher were compared to recorded steps and time (pedometers) for absolute error and transformed into percentages. The
absolute percent error across the five pedometer locations for steps (time in parentheses) ranged from 72.8% (65.7%) to
42.3% (32.6%). Across all five pedometer locations, registered steps were underestimated by approximately 52.9% ± 48.9%,
whereas pedometer registered time was overestimated by approximately 22.5% ± 53.8%. The findings indicate pedometers
may not accurately reflect the dynamic movement youth with disabilities engage during APE. |
| Description: | Paper presented to the 4th Annual Symposium on Graduate Research and Scholarly Projects (GRASP) held at the Hughes Metropolitan Complex, Wichita State University, April 25, 2008. Research completed at the Department of Physical Therapy, College of Health Professions |
| URI: | http://hdl.handle.net/10057/1347 |
| Appears in Collections: | PHT Graduate Student Conference Papers Proceedings: 4th Annual Symposium: Graduate Research and Scholarly Projects
|
Files in This Item:
| File |
Description |
Size | Format |
| grasp-2008-15.pdf | Article | 136Kb | Adobe PDF | View/Open |
|
All items in SOAR are protected by copyright, with all rights reserved.
|