SOAR
 
Wichita State University WSU Libraries

SOAR at Wichita State University Libraries >
Graduate School >
GRASP: Graduate Research and Scholarly Projects >
Proceedings: 3rd Annual Symposium: Graduate Research and Scholarly Projects >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10057/603

Title: Accuracy of pedometer steps and time for youth with disabilities
Authors: Balzer, Kelly
Chapman, Stan
Miller, Jennifer
Volk, Lisa
Keywords: Children with disabilities
Pedometers -- Testing
Issue Date: 27-Apr-2007
Publisher: Wichita State University. Graduate School.
Citation: Balzer, Kelly, Chapman Stan, Jr., Miller, Jennifer, Volk, Lisa (2007). Accuracy of pedometer steps and time for youth with disabilities. In Proceedings : 3rd Annual Symposium : Graduate Research and Scholarly Projects. Wichita, KS : Wichita State University, p.23-24
Series/Report no.: GRASP
v.3
Abstract: The goal of the study is to determine pedometer accuracy of steps and time for children with disabilities. Eleven girls and seven boys with multiple developmental disabilities participated in six, 80 meter self-paced walking trials. Pedometers were placed in five locations around the waist: front right [FR], front left [FL], back right [BR], back left [BL], and middle back [MB]. Each trial was video taped and actual steps and time were verified using video recordings. Accuracy was determined by percent difference between registered steps and time on the pedometers to actual steps and a time measured by video recordings. A high level of accuracy was found for the FR and BL locations for time, while only the FR location demonstrated adequate accuracy for steps. When one outlier with excessive weight status and slow walking speed was excluded, a high level of accuracy was observed across all locations for steps and time. Differences between pedometer locations were insignificant, with the exception of FL steps which demonstrated greater percent error scores and the pedometers measured time more accurately than steps. Time showed higher precision when compared to steps in both the full and outlier excluded samples. Location had minimal influence on accuracy, suggesting placements of the pedometer out of view (BR, BL, MB) can be used to minimize wearer interference. Concern needs to be exercised when using this pedometer with youth that exhibit a combination of excessive weight status and slow walking speed.
Description: Paper presented to the 3rd Annual Symposium on Graduate Research and Scholarly Projects (GRASP) held at the Hughes Metropolitan Complex, Wichita State University, April 27, 2007.
Research completed at the Department of Physical Therapy, College of Health Professions
URI: http://hdl.handle.net/10057/603
Appears in Collections:PHT Graduate Student Conference Papers
Proceedings: 3rd Annual Symposium: Graduate Research and Scholarly Projects

Files in This Item:

File Description SizeFormat
grasp24.pdfConference paper169KbAdobe PDFView/Open
Recommend this item

All items in SOAR are protected by copyright, with all rights reserved.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2006 MIT and Hewlett-Packard - Feedback